DS-K281X Series Access Controller
User Manual
Legal Informaon
©2022 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes for using and managing the Product. Pictures, charts, images andinstrucons
all other informaon hereinaer are for and only. The descripon explanaon informaon
contained in the Manual is subject to change, without due to noce, rmware updates or other
reasons. Please the latest version of this Manual at the Hikvision website ( nd hps://
www.hikvision.com/ ).
Please use this Manual with the guidance and assistance of professionals trained in supporng the
Product.
Trademarks
and other Hikvision's trademarks and logos are the properes of
Hikvision in various jurisdicons.
Other trademarks and logos are the menoned properes respecve of their owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT
DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED "AS IS" AND "WITH
ALL FAULTS AND ERRORS". HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR
PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION
BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES,
INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS
INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION,
WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY,
OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY
RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION,
PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS
INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY
TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE
SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW.
ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT
INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF
PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS.
YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE
DS-K281X Series Access Controller User Manual
i
DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR
PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED
TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN
RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER
PREVAILS.
DS-K281X Series Access Controller User Manual
ii
Available Model
Product Name Model
Access Controller DS-K2811
DS-K2812
DS-K2814
DS-K281X Series Access Controller User Manual
iii
Regulatory Informaon
FCC Informaon
Please take that changes or not expressly approved by the party responsibleaenon modicaon
for compliance could void the users authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protecon against harmful interference in a residenal installaon. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instrucons, may cause harmful interference to radio communicaons. However, there is
no guarantee that interference will not occur in a If this equipment doesparcular installaon.
cause harmful interference to radio or television recepon, which can be determined by turning
the equipment and on, the user is encouraged to try to correct the interference by one or moreo
of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit dierent from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
FCC Condions
This device complies with part 15 of the FCC Rules. is subject to the following twoOperaon
condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operaon.
EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked with "CE"
and comply therefore with the applicable harmonized European standards listed
DS-K281X Series Access Controller User Manual
iv
under the EMC 2014/30/EU, RE 2014/53/EU,the RoHS Direcve Direcve Direcve
2011/65/EU
2012/19/EU (WEEE Products marked with this symbol cannot be disposeddirecve):
of as unsorted municipal waste in the European Union. For proper recycling, return
this product to your local supplier upon the purchase of equivalent new equipment,
or dispose of it at designated collecon points. For more informaon see:
www.recyclethis.info
2006/66/EC (baery direcve): This product contains a that cannot bebaery
disposed of as unsorted municipal waste in the European Union. See the product
documentaon for The is marked with thisspecic baery informaon. baery
symbol, which may include leering to indicate cadmium (Cd), lead (Pb), or mercury
(Hg). For proper recycling, return the baery to your supplier or to a designated
collecon point. For more informaon see:www.recyclethis.info
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
This device complies with Industry Canada licence-exempt RSS standard(s). Operaon is subject to
the following two condions:
1. this device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired
operaon of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radioexempts de licence. L'exploitaon condions est autorisée aux deux suivantes :
1. l'appareil ne doit pas produire de brouillage, et
2. l'ulisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est d'en suscepble compromere fonconnement. le
Under Industry Canada this radio may only operate using an antenna of aregulaons, transmier
type and maximum (or lesser) gain approved for the transmier by Industry Canada. To reduce
potenal radio interference to other users, the antenna type and its gain should be so chosen that
the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
communicaon.
Conformément à la réglementaon d'Industrie Canada, le présent radio peut émeeur fonconner
avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour parl'émeeur
Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intenon des
autres ulisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une
communicaon sasfaisante.
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
DS-K281X Series Access Controller User Manual
v
Cet équipement doit être installé et à une distance minimale de 20 cm entre le radiateur etuli
votre corps.
DS-K281X Series Access Controller User Manual
vi
Safety Instrucon
These are intended to ensure that user can use the product correctly to avoid dangerinstrucons
or property loss.
The precauon measure is divided into Dangers and Cauons:
Dangers: Neglecng any of the warnings may cause serious injury or death.
Cauons: Neglecng cauons any of the may cause injury or equipment damage.
Dangers: Follow these safeguards to prevent
serious injury or death.
Cauons: Follow these precauons to prevent
potenal injury or material damage.
Danger:
All the electronic operaon should be strictly compliance with the electrical safety regulaons,
re prevenon regulaons and other related in your local region.regulaons
Please use the power adapter, which is provided by normal company. The power consumpon
cannot be less than the required value.
Do not connect several devices to one power adapter as adapter overload may cause over-heat
or re hazard.
Please make sure that the power has been disconnected before you wire, install or dismantle the
device.
When the product is installed on wall or ceiling, the device shall be rmly xed.
If smoke, odors or noise rise from the device, turn o the power at once and unplug the power
cable, and then please contact the service center.
Do not ingest baery, Chemical Burn Hazard.
This product contains a coin/buon baery. coin/buon baery cell If the cell is swallowed, it
can cause severe internal burns in just 2 hours and can lead to death.
Keep new and used baeries away from children. If the compartment does not closebaery
securely, stop using the product and keep it away from children. If you think might havebaeries
been swallowed or placed inside any part of the body, seek immediate medical aenon.
If the product does not work properly, please contact your dealer or the nearest service center.
Never aempt to disassemble the device yourself. (We shall not assume any responsibility for
problems caused by unauthorized repair or maintenance.)
DS-K281X Series Access Controller User Manual
vii
Cauons:
Do not drop the device or subject it to physical shock, and do not expose it to high
electromagnesm radiaon. Avoid the equipment on installaon vibraons surface or places
subject to shock (ignorance can cause equipment damage).
Do not place the device in extremely hot (refer to the of the device for the detailedspecicaon
operang temperature), cold, dusty or damp and do not expose it to highlocaons,
electromagnec radiaon.
The device cover for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low or heat source such as heater orvenlaon
radiator is forbidden (ignorance can cause re danger).
Do not aim the device at the sun or extra bright places. A blooming or smear may occur
otherwise (which is not a however), and malfuncon aecng the endurance of sensor at the
same me.
Please use the provided glove when open up the device cover, avoid direct contact with the
device cover, because the acidic sweat of the ngers may erode the surface of the devicecoang
cover.
Please use a and dry cloth when clean inside and outside surfaces of the device cover, doso
not use alkaline detergents.
Please keep all wrappers aer unpack them for future use. In case of any failure occurred, you
need to return the device to the factory with the original wrapper. Transportaon without the
original wrapper may result in damage on the device and lead to costs.addional
Improper use or replacement of the baery may result in hazard of explosion. Replace with the
same or equivalent type only. Dispose of used according to the baeries instrucons provided by
the baery manufacturer.
DS-K281X Series Access Controller User Manual
viii
Contents
Chapter 1 Prevenve Cauonary and Tips .................................................................................. 1
Chapter 2 Product .................................................................................................... 2Descripon
Chapter 3 Main Board .............................................................................................. 3Descripon
3.1 Single-Door Access Controller Main Board ......................................................... 3Descripon
3.2 Two-Door Access Controller Main Board ............................................................ 4Descripon
3.2.1 Four-Door Access Controller Main Board .................................................. 5Descripon
3.3 Component ......................................................................................................... 5Descripon
3.4 Charging Board .......................................................................................................... 7Baery
Chapter 4 Terminal Descripon .................................................................................................. 8
4.1 Single-Door Access Controller Terminal .............................................................. 8Descripon
4.2 Two-Door Access Controller Terminal ............................................................... 10Descripon
4.3 Four-Door Access Controller Terminal Descripon .............................................................. 13
Chapter 5 Installaon ............................................................................................................... 17
5.1 Wall ..................................................................................................................... 17Mounng
Chapter 6 Terminal Wiring ........................................................................................................ 19
6.1 Main Board Wiring ............................................................................................................... 19
6.2 Wiegand Card Reader Wiring ............................................................................................... 20
6.3 RS-485 Card Reader Wiring .................................................................................................. 20
6.4 Cathode Lock Wiring ............................................................................................................ 21
6.5 Anode Lock Wiring ............................................................................................................... 22
6.6 Alarm Output Wiring ........................................................................................................... 23
6.7 Exit Buon Wiring ................................................................................................................ 23
6.8 Door Contact Wiring ............................................................................................................ 24
6.9 Power Supply Wiring ............................................................................................................ 24
Chapter 7 Sengs .................................................................................................................... 26
7.1 1) ........................................................................................................ 26Inializaon (Opon
DS-K281X Series Access Controller User Manual
ix
7.2 2) ........................................................................................................ 26Inializaon (Opon
7.3 Relay Output NO/NC .............................................................................................. 27Sengs
7.3.1 Lock Relay Output Sengs ......................................................................................... 27
7.3.2 Alarm Relay Output ....................................................................................... 28Sengs
Chapter 8 Acvaon ................................................................................................................. 30
8.1 Acvate via SADP ................................................................................................................. 30
8.2 Acvate Soware Device via Client ...................................................................................... 31
Chapter 9 Client Soware Conguraon ................................................................................... 33
9.1 Conguraon Soware Flow of Client ................................................................................. 33
9.2 Device Management ............................................................................................................ 34
9.2.1 Add Device .................................................................................................................. 34
9.2.2 Reset Device Password ................................................................................................ 37
9.2.3 Manage Added Devices .............................................................................................. 38
9.3 Group Management ............................................................................................................. 39
9.3.1 Add Group ................................................................................................................... 39
9.3.2 Import Resources to Group ......................................................................................... 40
9.4 Person Management ............................................................................................................ 40
9.4.1 Add Organizaon ........................................................................................................ 40
9.4.2 Import and Export Person .......................................................... 41Idenfy Informaon
9.4.3 Get Person Informaon from Access Control Device .................................................. 43
9.4.4 Issue Cards to Persons in Batch ................................................................................... 44
9.4.5 Report Card Loss ......................................................................................................... 45
9.4.6 Set Card Issuing Parameters ........................................................................................ 45
9.5 Congure Schedule and Template ....................................................................................... 46
9.5.1 Add Holiday ................................................................................................................. 46
9.5.2 Add Template .............................................................................................................. 47
9.6 Set Access Group to Assign Access Authorizaon to Persons .............................................. 49
9.7 Congure Advanced ............................................................................................ 50Funcons
DS-K281X Series Access Controller User Manual
x
9.7.1 Remaining Unlocked/Locked ...................................................................... 50Congure
9.7.2 Congure An-Passback ............................................................................................. 51
9.7.3 Congure Mul-door Interlocking .............................................................................. 52
9.7.4 First Person In ............................................................................................. 53Congure
9.7.5 Congure Mul-Factor Authencaon ....................................................................... 54
9.7.6 Card Reader Mode and Schedule ...................................... 56Congure Authencaon
9.7.7 Device Parameters ...................................................................................... 58Congure
9.7.8 Device Parameters ...................................................................................... 62Congure
9.8 Door Control ........................................................................................................................ 63
9.8.1 Control Door Status ..................................................................................................... 63
9.8.2 Check Real-Time Access Records ................................................................................ 64
Appendix A. Tips for Scanning Fingerprint ................................................................................ 65
Appendix B. DIP Switch Descripon .......................................................................................... 67
Appendix C. Custom Wiegand Rule Descripons ....................................................................... 68
Appendix D. Matrix and Device Command ...................................................... 70Communicaon
DS-K281X Series Access Controller User Manual
xi
Chapter 1 Prevenve Cauonary and Tips
Before connecng operang and your device, please be advised of the following ps:
Ensure unit is installed in a well-venlated, dust-free environment.
Keep all liquids away from the device.
Ensure environmental condions meet factory specicaons.
Ensure unit is properly secured to a rack or shelf. Major shocks or jolts to the unit as a result of
dropping it may cause damage to the electronics within the unit.sensive
Use the device in with an UPS if possible.conjuncon
Power down the unit before connecng disconnecng and accessories and peripherals.
A factory recommended HDD should be used for this device.
Improper use or replacement of the baery may result in hazard of explosion. Replace with the
same or equivalent type only. Dispose of used according to the provided bybaeries instrucons
the manufacturer.
It is recommended to choose a 12 V 7 AH lead-acid that meets the IEC 60896 standard.baery
The wiring method is shown in the following baery gure.
DS-K281X Series Access Controller User Manual
1
Chapter 2 Product Descripon
32-bit high-speed processor
Supports TCP/IP communicaon. communicaon The data is specially encrypted to relieve the
concern of privacy leak
Supports recognion and storage of card No. with maximum length of 20
Supports up to 10,000 cards and 50,000 card recordspresenng
Supports mul-door funcon, interlock inner-device an-passback funcon, mulple
authencaons open door with funcon, rst funcon, card super password M1 cardfuncon,
encrypon, funcon online upgrade and remote control of the doors
IP address conict detecon
Supports RS-485 interface and Wiegand interface for accessing card reader. Wiegand interface
supports W26, W34 and is with the third-party card reader with Wiegand interfacecompable
Various indicators to show dierent status
Supports record storage funcon oine insucient when the device is and storage space
storage alarm funcon
Data can be permanently saved the access controller is powered aer o
Supports I/O linkage and event linkage
DS-K281X Series Access Controller User Manual
2
Chapter 3 Main Board Descripon
3.1 Single-Door Access Controller Main Board Descripon
Figure 3-1 Single-Door Access Controller Main Board
DS-K281X Series Access Controller User Manual
3
3.2 Two-Door Access Controller Main Board Descripon
Figure 3-2 Two-Door Access Controller Main Board
DS-K281X Series Access Controller User Manual
4
3.2.1 Four-Door Access Controller Main Board Descripon
Figure 3-3 Four-Door Access Controller Main Board
3.3 Component Descripon
You can view the device's components and their descripons.
Take four-door access controller as an example, the component diagram is shown below.
DS-K281X Series Access Controller User Manual
5
Figure 3-4 Four-Door Access Controller Component Diagram
Table 3-1 Four-Door Access Controller Component Descripon
No. Component Descripon
1 Power Indicator
2 Lock Indicator
3 Hardware Inializaon and Normal Working Choice
4 Network Indicator
5 Running Indicator
6 RS-485 Communicaon Indicator
7 Alarm Output Indicator
8 Door Relay Output Status (NC/NO) Choice
DS-K281X Series Access Controller User Manual
6
3.4 Charging BoardBaery
Figure 3-5 Charging BoardBaery
Note
The charging boards are only for devices that support baery baery.
DS-K281X Series Access Controller User Manual
7
Chapter 4 Terminal Descripon
4.1 Single-Door Access Controller Terminal Descripon
You can view the single-door access controller's terminal descripon.
Figure 4-1 Single-Door Access Controller Main Board
DS-K281X Series Access Controller User Manual
8
Table 4-1 Single-Door Access Controller Terminal Descripon
No. Four-Door Access Controller
A1~A28 Wiegand Reader 1~4 OK Indicator of Card
Reader Control Output
(Valid Card Output)
ERR Indicator of Card
Reader Control Output
(Invalid Card Output)
BEEP Card Reader Buzzer
Control Output
W1 Wiegand Card Reader
Data Input Data1
W0 Wiegand Card Reader
Data Input Data0
12 V Wiegand Card Reader
Data Input Data0
G Grounding
B1 Power Supply G Grounding
B2 DC_IN Power In
B3 RS-485 Interface G Grounding
B4 485- Card Reader 485-
B5 485+ Card Reader 485+
B6~B13 Alarm Output COM4 Alarm Relay 4Output
(Dry Contact)
NO/NC4
COM3 Alarm Relay 3 Output
(Dry Contact)
NO/NC3
COM2 Alarm Relay 2 Output
(Dry Contact)
NO/NC2
COM1 Alarm Relay 1 Output
(Dry Contact)
NO/NC1
C1 Event In C4 Event In 4
C2 G Grounding
DS-K281X Series Access Controller User Manual
9
No. Four-Door Access Controller
C3 C3 Event In 3
C4 Tamper C2 Reserved
C5 G Grounding
C6 C1 Tamper
C7 Event In C6 Event In 6
C8 G Grounding
C9 C5 Event In 5
C10~C15 Lock 1 NC Lock Relay Output (Dry
Contact)
COM
NO
B Exit InBuon
G Grounding
S Door Contact
Note
RS-485 card reader ID should be set as 1to 2. The table displayed below shows the relaonship
between the door No. and the ID.
Door No. RS-485 Card Reader ID Descripon
Door 1 1 Enter
2 Exit
For single-door access controller, the Wiegand card reader and door's is as followsrelaonship
by default.
Door No. Wiegand Card Reader Descripon
Door 1 1 Enter
2 Exit
4.2 Two-Door Access Controller Terminal Descripon
You can view the two-door access controller's terminal descripon.
DS-K281X Series Access Controller User Manual
10
Figure 4-2 Two-Door Access Controller Main Board
Table 4-2 Two-Door Access Controller Terminal Descripon
No. Four-Door Access Controller
A1~A28 Wiegand Reader 1~4 OK Indicator of Card
Reader Control Output
(Valid Card Output)
ERR Indicator of Card
Reader Control Output
(Invalid Card Output)
BEEP Card Reader Buzzer
Control Output
W1 Wiegand Card Reader
Data Input Data1
DS-K281X Series Access Controller User Manual
11
No. Four-Door Access Controller
W0 Wiegand Card Reader
Data Input Data0
12 V Wiegand Card Reader
Data Input Data0
G Grounding
B1 Power Supply G Grounding
B2 DC_IN Power In
B3 RS-485 Interface G Grounding
B4 485- Card Reader 485-
B5 485+ Card Reader 485+
B6~B13 Alarm Output COM4 Alarm Relay 4Output
(Dry Contact)
NO/NC4
COM3 Alarm Relay 3 Output
(Dry Contact)
NO/NC3
COM2 Alarm Relay 2 Output
(Dry Contact)
NO/NC2
COM1 Alarm Relay 1 Output
(Dry Contact)
NO/NC1
C1 Event In C4 Event In 4
C2 G Grounding
C3 C3 Event In 3
C4 Tamper C2 Reserved
C5 G Grounding
C6 C1 Tamper
C7 Event In C6 Event In 6
C8 G Grounding
C9 C5 Event In 5
C10~C21 Lock 1~Lock 2 NC Lock Relay Output (Dry
Contact)
COM
DS-K281X Series Access Controller User Manual
12
No. Four-Door Access Controller
NO
B Exit InBuon
G Grounding
S Door Contact
Note
RS-485 card reader ID should be set as 1 to 8.
Door No. RS-485 Card Reader ID Descripon
Door 1 1 Enter
2 Exit
Door 2 3 Enter
4 Exit
For two-door access controller, the Wiegand card reader and door's is as follows byrelaonship
default.
Door No. Wiegand Card Reader Descripon
Door 1 1 Enter
2 Exit
Door 2 3 Enter
4 Exit
4.3 Four-Door Access Controller Terminal Descripon
You can view the four-door access controller's terminal descripon.
DS-K281X Series Access Controller User Manual
13
Figure 4-3 Four-Door Access Controller Main Board
Table 4-3 Four-Door Access Controller Terminal Descripon
No. Four-Door Access Controller
A1~A28 Wiegand Reader 1~4 OK Indicator of Card
Reader Control Output
(Valid Card Output)
ERR Indicator of Card
Reader Control Output
(Invalid Card Output)
BEEP Card Reader Buzzer
Control Output
W1 Wiegand Card Reader
Data Input Data1
DS-K281X Series Access Controller User Manual
14
No. Four-Door Access Controller
W0 Wiegand Card Reader
Data Input Data0
12 V Wiegand Card Reader
Data Input Data0
G Grounding
B1 Power Supply G Grounding
B2 DC_IN Power In
B3 RS-485 Interface G Grounding
B4 485- Card Reader 485-
B5 485+ Card Reader 485+
B6~B13 Alarm Output COM4 Alarm Relay 4Output
(Dry Contact)
NO/NC4
COM3 Alarm Relay 3 Output
(Dry Contact)
NO/NC3
COM2 Alarm Relay 2 Output
(Dry Contact)
NO/NC2
COM1 Alarm Relay 1 Output
(Dry Contact)
NO/NC1
C1 Event In C4 Event In 4
C2 G Grounding
C3 C3 Event In 3
C4 Tamper C2 Reserved
C5 G Grounding
C6 C1 Tamper
C7~C30 Lock 1~4 NC Lock Relay Output (Dry
Contact)
COM
NO
B Exit InBuon
DS-K281X Series Access Controller User Manual
15
No. Four-Door Access Controller
G Grounding
S Door Contact
Note
RS-485 card ID should be set as 1 to 8.
Door No. RS-485 Card Reader ID Descripon
Door 1 1 Enter
2 Exit
Door 2 3 Enter
4 Exit
Door 3 5 Enter
6 Exit
Door4 7 Enter
8 Exit
For four-door access controller, the Wiegand card reader and door's is as follows byrelaonship
default.
Door No. Wiegand Card Reader Descripon
Door 1 1 Enter
/ Exit
Door 2 2 Enter
/ Exit
Door 3 3 Enter
/ Exit
Door 4 4 Enter
/ Exit
DS-K281X Series Access Controller User Manual
16
Chapter 5 Installaon
5.1 Wall Mounng
The access controller can be installed on the wall.
Steps
1. Note
In the process of installing, the cable through the knockout, the knockout should beaer roung
sealed with ame-retardant clay or a plug that achieves the of V-1.rang
Open and take the case door.o
Figure 5-1 Open the case door
2. Secure the device on the wall with expansion screws.
DS-K281X Series Access Controller User Manual
17
Figure 5-2 Secure the device
3. Aer wiring, recover the case door and boom.
Note
When wiring, you can open knockouts to your actual needs.
DS-K281X Series Access Controller User Manual
18
Chapter 6 Terminal Wiring
Terminal Wiring of the Access Controller.Descripon
6.1 Main Board Wiring
You can view the main board wiring diagram.
Figure 6-1 Access Controller Main Board Wiring
DS-K281X Series Access Controller User Manual
19
6.2 Wiegand Card Reader Wiring
You can view the Wiegand card reader wiring diagram.
Figure 6-2 Wiegand Card Reader Wiring Diagram
Note
You must connect the OK/ERR/BZ, if using access controller to control the LED and buzzer of the
Wiegand card reader.
6.3 RS-485 Card Reader Wiring
You can view the RS-485 card reader wiring diagram.
DS-K281X Series Access Controller User Manual
20
Figure 6-3 RS-485 Card Reader Wiring Diagram
Note
If the card reader is installed too far away from the access controller, you can use an external
power supply.
6.4 Cathode Lock Wiring
You can view the cathode lock wiring diagram.
DS-K281X Series Access Controller User Manual
21
Figure 6-4 Wiring Diagram of Cathode Lock
6.5 Anode Lock Wiring
You can view the anode lock wiring diagram.
Figure 6-5 Wiring Diagram of Anode Lock
DS-K281X Series Access Controller User Manual
22
6.6 Alarm Output Wiring
You can view the Alarm Output Wiring diagram.
Figure 6-6 Alarm Output Wiring
6.7 Exit Buon Wiring
You can view the exit wiring diagrambuon
Figure 6-7 Exit WiringBuon
DS-K281X Series Access Controller User Manual
23
6.8 Door Contact Wiring
You can view the door contact wiring diagram.
Figure 6-8 Door Contact Wiring
6.9 Power Supply Wiring
You can view the power supply wiring diagram.
DS-K281X Series Access Controller User Manual
24
Figure 6-9 Power Supply Wiring
DS-K281X Series Access Controller User Manual
25
Chapter 7 Sengs
7.1 1)Inializaon (Opon
You can inialize the device with the jumper cap.
Steps
1. Remove the jumper cap from the Normal terminal.
2. Cut the power and restart the access controller.o
The controller buzzer buzzes a long beep.
3. When the beep stopped, plug the jumper cap back to Normal.
4. Cut o the power and restart the access controller.
Figure 7-1 JumperInializaon
Note
The device will restore all the parameters to the default and all the deviceinializaon sengs
event logs will be deleted.
7.2 2)Inializaon (Opon
You can inialize the device with the jumper cap.
Steps
1. Move the jumper cap from Normal to Inial.
2. Cut the power and restart the access controller.o
The controller buzzer buzzes a long beep.
3. When the beep stopped, move the jumper cap back to Normal.
4. Cut o the power and restart the access controller.
DS-K281X Series Access Controller User Manual
26
Figure 7-2 JumperInializaon
Note
The device will restore all the parameters to the default and all the deviceinializaon sengs
event logs will be deleted.
7.3 Relay Output NO/NC Sengs
7.3.1 Lock Relay Output Sengs
You can view the NO/NC status of the lock relay.
Lock Relay NO Status
Figure 7-3 NO Status
DS-K281X Series Access Controller User Manual
27
Lock Relay NC Status
Figure 7-4 NC Status
7.3.2 Alarm Relay Output Sengs
You can view the NO/NC status of the alarm relay.
Alarm Relay Output NO Status
Figure 7-5 NO Status
DS-K281X Series Access Controller User Manual
28
Alarm Relay Output NC Status
Figure 7-6 NC Status
DS-K281X Series Access Controller User Manual
29
Chapter 8 Acvaon
You should acvate the device before the rst Aer login. powering on the device, the system will
switch to Device Acvaon page.
Acvaon via the device, SADP tool and the client soware are supported.
The default values of the device are as follows:
The default IP address: 192.0.0.64
The default port No.: 8000
The default user name: admin
8.1 Acvate via SADP
SADP is a tool to detect, acvate and modify the IP address of the device over the LAN.
Before You Start
Get the SADP soware from the supplied disk or the website ocial hp://
www.hikvision.com/en/ , and install the SADP according to the prompts.
The device and the PC that runs the SADP tool should be within the same subnet.
The following steps show how to acvate a device and modify its IP address. For batch acvaon
and IP addresses refer to for details.modicaon, User Manual of SADP
Steps
1. Run the SADP soware and search the online devices.
2. Find and select your device in online device list.
3. Input new password (admin password) and conrm the password.
Cauon
STRONG PASSWORD RECOMMENDED-We highly recommend you create a strong password of
your own choosing (using a minimum of 8 characters, including upper case leers, lower case
leers, numbers, and special characters) in order to increase the security of your product. And
we recommend you reset your password regularly, especially in the high security system,
reseng the password monthly or weekly can protect your product.beer
Note
Characters containing admin and nimda are not supported to be set as password.acvaon
4. Click Acvate to start acvaon.
DS-K281X Series Access Controller User Manual
30
Status of the device becomes successful Acve aer acvaon.
5. Modify IP address of the device.
1) Select the device.
2) Change the device IP address to the same subnet as your computer by either modifying the IP
address manually or checking .Enable DHCP
3) Input the admin password and click to Modify acvate your IP address modicaon.
8.2 Acvate Soware Device via Client
For some devices, you are required to create the password to acvate them before they can be
added to the soware and work properly.
Steps
Note
This should be supported by the device.funcon
1. Enter the Device Management page.
2. Click on the right of Device Management Device and select .
3. Click to show the online device area.Online Device
The searched online devices are displayed in the list.
4. Check the device status (shown on column) and select an Security Level inacve device.
5. Click Acvate to open the dialog.Acvaon
6. Create a password in the password and the password.eld, conrm
DS-K281X Series Access Controller User Manual
31
Cauon
The password strength of the device can be checked. We highly recommend youautomacally
change the password of your own choosing (using a minimum of 8 characters, including at least
three kinds of following categories: upper case lower case numbers, and specialleers, leers,
characters) in order to increase the security of your product. And we recommend you reset your
password regularly, especially in the high security system, the password monthly orreseng
weekly can beer protect your product.
Proper conguraon of all passwords and other security is the responsibility of thesengs
installer and/or end-user.
Note
Characters containing admin and nimda are not supported to be set as password.acvaon
7. Click to OK acvate the device.
DS-K281X Series Access Controller User Manual
32
Chapter 9 Client Soware Conguraon
You can call the hotline to get the iVMS-4200 client soware installaon package.
9.1 Conguraon Soware Flow of Client
Follow the diagram below to on the client ow congure soware.
Figure 9-1 Flow Diagram of Conguraon Soware on Client
DS-K281X Series Access Controller User Manual
33
9.2 Device Management
The client supports managing access control devices and video intercom devices.
Example
You can control entrance & exit and manage adding access control devices to theaendance aer
client; you can perform video intercom with the indoor staons staons. and door
9.2.1 Add Device
Aer running the client, devices should be added to the client for the remote conguraon and
management.
Aer adding device(s), you can select a device and click Remote Conguraon to congure further
parameters of the selected device if needed. You can also
Note
For some models of devices, you can open its general or advanced parameters conguraon
window. To open the original remote conguraon window, press and click CTRL Remote
Conguraon.
Aer adding access control devices, you can select access control device from the list and click
Device Status to view the device status.
Add Device by IP Address or Domain Name
You can add device by IP address or domain name.
Perform this task if you need to add device by IP address or domain name.
Steps
1. Open the Device Management module.
2. Click tab and select as the device type.Device Hikvision Device
3. Click to open the Add window.Add
4. Select IP/Domain as the adding mode.
5. Input the required informaon, including nickname, IP address, port number, user name, and
password.
Address
Input the device IP addresss or domain name.
Port
Input the device port No. The default value is 8000.
User Name
DS-K281X Series Access Controller User Manual
34
Input the device user name. By default, the user name is admin.
Password
Input the device password.
Cauon
The password strength of the device can be automacally checked. We highly recommend you
change the password of your own choosing (using a minimum of 8 characters, including at
least three kinds of following categories: upper case lower case leers, leers, numbers, and
special characters) in order to increase the security of your product. And we recommend you
reset your password regularly, especially in the high security system, the passwordreseng
monthly or weekly can beer protect your product.
Proper conguraon of all passwords and other security is the responsibility of thesengs
installer and/or end-user.
6. Oponal: Synchronize Device TimeCheck to synchronize the device with the PC runningme
the client aer adding the device to the client.
7. Oponal: Export to GroupCheck to create a group by the device name.
Note
You can import all the channels of the device to the corresponding group by default.
8. Oponal: Add the devices.oine
1) Check .Add DeviceOine
2) Input the required informaon, including the device channel number and alarm input
number.
3) Click .Add
When the oine soware automacally. device comes online, the will connect it
9. Click to add the device.Add
Import Devices in a Batch
The devices can be added to the in batch by the device soware inpung informaon pre- in the
dened CSV le.
Perform this task to import devices in a batch.
Steps
1. Enter the Device Management page
2. Click to open the adding device window.Device → Hikvision Device → Add
3. Select Batch Import as the adding mode.
4. Click Export Template and then save the pre-dened template (CSV on your PC.le)
5. Open the exported template le and input the required informaon of the devices to be added
on the corresponding column.
Adding Mode
DS-K281X Series Access Controller User Manual
35
You can input , , , , , or which indicated 02345 6 dierent adding modes. indicates that the0
device is added by IP address or domain name; indicates that the device is added via IP2
server; indicates that the device is added via HiDDNS; indicates that the device is added via3 4
EHome protocol; indicates that the device is added by serial port; indicates that the device5 6
is added via Hik-Connect.
Address
Edit the address of the device. If you set as the adding mode, you should input the IP address0
or domain name of the device; if you set as the adding mode, you should input the IP2
address of the PC that installs the IP Server; if you set as the adding mode, you should input3
www.hik-online.com.
Port
Input the device port No. The default value is 8000.
Device Informaon
If you set as the adding mode, this is not required; if you set as the adding mode, input0eld 2
the device ID registered on the IP Server; if you set as the adding mode, input the device3
domain name registered on HiDDNS server; if you set as the adding mode, input the EHome4
account; if you set as the adding mode, input the device serial No.6
User Name
Input the device user name. By default, the user name is admin.
Password
Input the device password.
Cauon
The password strength of the device can be checked. We highly recommend youautomacally
change the password of your own choosing (using a minimum of 8 characters, including at
least three kinds of following categories: upper case leers, leers, lower case numbers, and
special characters) in order to increase the security of your product. And we recommend you
reset your password regularly, especially in the high security system, reseng the password
monthly or weekly can beer protect your product.
Proper conguraon of all passwords and other security is the responsibility of thesengs
installer and/or end-user.
Add DeviceOine
You can input to enable adding the 1oine soware automacally device, and then the will
connect it when the device comes online. indicates disabling this oine 0funcon.
Export to Group
You can input to create a group by the device name (nickname). All the channels of the1
device will be imported to the corresponding group by default. indicates disabling this0
funcon.
DS-K281X Series Access Controller User Manual
36
Channel Number
If you set for Add Device, input the channel number of the device. If you set for Add1Oine 0
Oine eld Device, this is not required.
Alarm Input Number
If you set for Add 1Oine Device, input the alarm input number of the device. If you set for0
Add Device, this is not required.Oine eld
Serial Port No.
If you set as the adding mode, input the serial port No. for the access control device.5
Baud Rate
If you set as the adding mode, input the baud rate of the access control device.5
DIP
If you set as the adding mode, input the DIP address of the access control device.5
Hik-Connect Account
If you set as the adding mode, input the Hik-Connect account.6
Hik-Connect Password
If you set as the adding mode, input the Hik-Connect account password.6
6. Click and select the template le.
7. Click to import the devices.Add
9.2.2 Reset Device Password
If you forgot the password of the detected online devices, you can reset the device password via
the client.
Steps
1. Enter Device Management page.
2. Click to show the online device area.Online Device
All the online devices sharing the same subnet will be displayed in the list.
3. Select the device from the list and click on the column.Operaon
4. Reset the device password.
-Click Generate Download to pop up the QR Code window and click to save the QR code to
your PC. You can also take a photo of the QR code to save it to your phone. Send the picture
to our technical support.
Note
For the following for the password, contact our technical support.operaons reseng
DS-K281X Series Access Controller User Manual
37
Cauon
The password strength of the device can be checked. We highly recommend youautomacally
change the password of your own choosing (using a minimum of 8 characters, including at least
three kinds of following categories: upper case lower case numbers, and specialleers, leers,
characters) in order to increase the security of your product. And we recommend you reset your
password regularly, especially in the high security system, the password monthly orreseng
weekly can beer protect your product.
Proper conguraon of all passwords and other security is the responsibility of thesengs
installer and/or end-user.
9.2.3 Manage Added Devices
Aer adding devices to device list, you can manage the added devices including deviceeding
parameters, remote conguraon, viewing device status, etc.
Table 9-1 Manage Added Devices
Edit Device Click to edit device informaon including device name, address, user
name, password, etc.
Delete Device Check one or more devices, and click Delete to delete the selected
devices.
Remote Conguraon On the device list page, click in the column to performOperaon
remote conguraon for a device. The is in the rightmost column of
the Device page. For details, refer to the user manual of device.
View Device Status Click to view device status, including door No., door status, etc.
Note
For dierent devices, you will view dierent informaon about device
status.
View Online User Click to view the details of online user who access the device,
including user name, user type, IP address and login me.
Refresh Device
Informaon
Click to refresh and get the latest device informaon.
Upgrade Device View device status in the Firmware Upgrade column, check one or more
upgradable devices, and click Upgrade Device Firmware to upgrade the
selected devices. For details, refer to .
DS-K281X Series Access Controller User Manual
38
Get Events from Device Check one device, and click Get Events from Device to synchronize
events. For details, refer to .
Export Device Click , set the saving path and select device type to exportExport Device
the device details (such as device type, IP address, and port No.) to your
local PC.
Note
The super user can enable Password Protecon and enter the
password, then the exported of device le informaon will be
encrypted.
9.3 Group Management
The client provides groups to manage the added resources in dierent groups. You can group the
resources into dierent groups according to the resources' locaons.
Example
For example, on the 1st oor, there mounted 16 doors, 64 alarm inputs, and 16 alarm outputs. You
can organize these resources into one group (named 1st Floor) for convenient management. You
can control door status, and do some other operaons of the devices managing the resourcesaer
by groups.
9.3.1 Add Group
You can add group to organize the added device for convenient management.
Steps
1. Enter the Device Management module.
2. Click Device Management → Group to enter the group management page.
3. Create a group.
-Click and enter a group name as you want.Add Group
-Click Create Group by Device Name and select an added device to create a new group by the
name of the selected device.
Note
The resources (such as alarm inputs/outputs, access points, etc.) of this device will be
imported to the group by default.
DS-K281X Series Access Controller User Manual
39
9.3.2 Import Resources to Group
You can import the device resources (such as alarm inputs/outputs, access points, etc.) to the
added group in a batch.
Before You Start
Add a group for managing devices. Refer to Add Group .
Steps
1. Enter the Device Management module.
2. Click Device Management → Group to enter the group management page.
3. Select a group from the group list and select the resource type as Access Point Alarm Input, ,
Alarm Output, etc.
4. Click .Import
5. Select the thumbnails/names of the resources in the thumbnail/list view.
Note
You can click or to switch the resource display mode to thumbnail view or to list view.
6. Click to import the selected resources to the group.Import
9.4 Person Management
You can add person to the system for further such as access control, videoinformaon operaons
intercom, and etc. You can manage the added persons such as issuing cards tome aendance,
them in a batch, imporng exporng and person in a batch, etc.informaon
9.4.1 Add Organizaon
You can add an organizaon and import person informaon organizaon to the for eecve
management of the persons. You can also add a surbodinate organizaon for the added one.
Steps
1. Enter Person module.
2. Select a parent organizaon le upper-le in the column and click in the Add corner to add an
organizaon.
3. Create a name for the added organizaon.
Note
Up to 10 levels of organizaons can be added.
4. Oponal: Perform the following operaon(s).
Edit Organizaon Hover the mouse on an added organizaon and click to edit its name.
DS-K281X Series Access Controller User Manual
40
Delete
Organizaon
Hover the mouse on an added organizaon and click to delete it.
Note
The lower-level organizaons will be deleted as well if you delete an
organizaon.
Make sure there is no person added under the organizaon, or the
organizaon cannot be deleted.
Show Persons in
Sub Organizaon
Check Show Persons in Sub Organizaon and select an organizaon to
show persons in its sub organizaons.
9.4.2 Import and Export Person Idenfy Informaon
You can import the informaon mulple of persons to the client soware in a batch. Meanwhile,
you can also export the person and save them in your PC.informaon
Import Person Informaon
You can import the informaon mulple identy informaon, ngerprint of persons (including
data, and linked card number) to the client in a batch by an Excelngerprint soware imporng
le from the local PC.
Perform this task when you need to import the person informaon to the client in a batch.
Steps
1. Enter Access Control → Person and Card .
2. Click Import Persons Person and select Informaon as the content to import.
3. In the pop-up window, click Download Template for PersonImporng to download the
template rst.
4. Input the person informaon in the downloaded template.
f1 to f10
The person's ngerprint data.
f1card to f10card
The linked card number. If it links to no card, leave it empty.ngerprint's
Note
If the person has cards, separate the card No. with semicolon.mulple
5. Enter Access Control → Person and Card Import Person , click and select the Excel withle
person informaon.
6. Click to start OK imporng.
DS-K281X Series Access Controller User Manual
41
Note
If the person No. already exists in the client soware's database, it will replace the person
informaon automacally aer imporng.
Import Person Pictures
Aer imporng face pictures for the added persons to the client, the persons in the pictures can be
idened by an added face terminal. You can either import person pictures one byrecognion
one, or import mulple me pictures at a according to your need.
Before You Start
Be sure to have imported person informaon to the client beforehand.
Steps
1. Enter the Person module.
2. Select an added organizaon in the list, or click in the Add upper-le corner to add an
organizaon and then select it.
3. Click to open the Import panel and check Import Face.
4. Oponal: Verify by DeviceEnable to check whether face device managed in therecognion
client can recognize the face in the photo.
5. Click to select a face picture le.
Note
The (folder of) face pictures should be in ZIP format.
Each picture should be in JPG format and should be no larger than 200 KB.le
Each picture should be named as "Person ID_Name". The Person ID should be the samele
with that of the imported person informaon.
6. Click to start Import imporng.
The progress and result will be displayed.imporng
Export Person Informaon
You can export the added persons' to the local PC in an Excel informaon le.
Perform this task when you need to export the added person informaon in a batch.
Steps
1. Enter Access Control → Person and Card module.
2. Click Export Person Person and select Informaon as the content to export.
3. Select the path for saving the exported Excel le.
4. Select the items of person informaon to export.
5. Click to start OK exporng.
DS-K281X Series Access Controller User Manual
42
f1 to f10
The person's ngerprint data.
f1card to f10card
The linked card number. If it links to no card, leave it empty.ngerprint's
Export Person Pictures
You can export face picture of the added persons and save in your PC.le
Before You Start
Make sure you have added persons and their face pictures to an organizaon.
Make sure you have enabled the Export Person Informaon to display the funcon Export
buon. See for details.
Steps
1. Enter the Person module.
2. Oponal: Select an organizaon in the list.
Note
All persons' face pictures will be exported if you do not select any organizaon.
3. Click on the top menu bar.Export
4. Enter the super user name and password for vericaon.
The Export panel is displayed.
5. Check Face as the content to export.
6. Click and set an Export encrypon key to encrypt the exported le.
Note
The exported is in ZIP format.le
The exported face picture is named as "Person ID_Name_0" ("0" is for a full-frontal face).
9.4.3 Get Person Informaon from Access Control Device
If the access control device has been congured with person informaon (including person details,
ngerprint, and issued card informaon), you can get the person informaon from the added
device and import them to the client for further operaons.
DS-K281X Series Access Controller User Manual
43
Steps
Note
If the person name stored in the device is empty, the person name will be with the issuedlled
card No. to the client.aer imporng
If the card number or person ID (employee ID) stored on the device already exists in the client
database, the person with this card number or person ID will not be imported to the client.
1. Enter Person module.
2. Select an organizaon to import the persons.
3. Click Get from Device.
4. Select an added access control device or the enrollment staon from the drop-down list.
Note
If you select the enrollment staon, you should click , and enter IP address, port No., userLogin
name and password of the device.
5. Select the .Geng Mode
Note
The mode varies according to geng dierent devices. The access control device supports
geng the person by employee ID. Up to 5 employee IDs can be eachinformaon specied
me.
6. Click to start the person Import imporng informaon to the client.
Note
Up to 2,000 persons and 5,000 cards can be imported.
The person informaon, including person details, person's ngerprint informaon (if
congured), and the linked cards (if congured), will be imported to the selected organizaon.
9.4.4 Issue Cards to Persons in Batch
The client provides a convenient way to issue cards to persons in a batch.mulple
Steps
1. Enter Person module.
2. Click Batch Issue Cards.
All the added persons with no card issued will display.
3. Set the card issuing parameters. For details, refer to Set Card Issuing Parameters .
4. Click to the card enrollment Inialize inialize staon or card reader to make it ready for issuing
cards.
5. Click the card number column and enter the card number.
-Place the card on the card enrollment staon.
DS-K281X Series Access Controller User Manual
44
-Swipe the card on the card reader.
-Enter the card number manually and press key on your keyboard.Enter
The card number will be read and the card will be issued to the person in the list.automacally
6. Repeat the above step to issue the cards to the persons in the list in sequence.
9.4.5 Report Card Loss
If the person lost his/her card, you can report the card loss so that the card's related access
authorizaon inacve. will be
Steps
1. Enter Person module.
2. Select the person you want to report card loss for and click to open the Edit Person window.Edit
3. In the Credenal panel, click on the added card to set this card as lost card.→ Card
Aer reporng card loss, the access of this card will be invalid and Otherauthorizaon inacve.
person who gets this card cannot access the doors by swiping this lost card.
4. Oponal: If the lost card is found, you can click to cancel the loss.
Aer cancelling card loss, the access of the person will be valid and authorizaon acve.
5. If the lost card is added in one access group and the access group is applied to the device
already, aer reporng card loss or cancelling card loss, a window will pop up to you tonofy
apply the changes to the device. applying to device, these changes can take Aer eect on the
device.
9.4.6 Set Card Issuing Parameters
The client provides two modes for reading a card's number: via card enrollment or via thestaon
card reader of the access control device. If a card enrollment staon is available, connect it to the
PC running the client by USB interface or COM, and place the card on the card enrollment to read
the card number. If not, you can also swipe the card on the card reader of the added access control
device to get the card number. As a result, before issuing a card to one person, you need to set the
card issuing parameters including the issuing mode and related parameters.
When adding a card to one person, click Sengs to open the Card Issuing window.Sengs
Local Mode: Issue Card by Card Enrollment
Staon
Connect a card enrollment staon to the PC running the client. You can place the card on the card
enrollment to get the card number.staon
Card Enrollment Staon
Select the model of the connected card enrollment staon
DS-K281X Series Access Controller User Manual
45
Note
Currently, the supported card enrollment staon models include DS-K1F100-D8, DS-K1F100-M,
DS-K1F100-D8E, and DS-K1F180-D8E.
Card Type
This is only available when the model is DS-K1F100-D8E or DS-K1F180-D8E.eld
Select the card type as EM card or IC card according to the actual card type.
Serial Port
It is only available when the model is DS-K1F100-M.
Select the COM the card enrollment staon connects to.
Buzzing
Enable or disable the buzzing when the card number is read successfully.
Card No. Type
Select the type of the card number according to actual needs.
M1 Card Encrypon
This is only available when the model is DS-K1F100-D8, DS-K1F100-D8E, or DS-K1F180-D8E.eld
If the card is M1 card, and if you need to enable the M1 Card Encrypon funcon, you should
enable this and select the sector of the card to encrypt.funcon
Remote Mode: Issue Card by Card Reader
Select an access control device added in the client and swipe the card on its card reader to read
the card number.
9.5 Congure Schedule and Template
You can congure the template including holiday and week schedule. the template,Aer seng
you can adopt the congured template to access groups when the access groups, so thatseng
the access group will take eect me duraons in the of the template.
Note
For access group refer to sengs, Set Access Group to Assign Access to PersonsAuthorizaon .
9.5.1 Add Holiday
You can create holidays and set the days in the holidays, including start date, end date, and holiday
duraon in one day.
DS-K281X Series Access Controller User Manual
46
Steps
Note
You can add up to 64 holidays in the soware system.
1. Click Access Control → Schedule → Holiday to enter the Holiday page.
2. Click on the panel.Add le
3. Create a name for the holiday.
4. Oponal: Enter the or some of this holiday in the Remark box.descripons nocaons
5. Add a holiday period to the holiday list and congure duraon. the holiday
Note
Up to 16 holiday periods can be added to one holiday.
1) Click in the Holiday List Add eld.
2) Drag the cursor to draw the which means in that of theme duraon, duraon me,
congured acvated. access group is
Note
Up to 8 me duraons can be set to one holiday period.
3) Perform the following to edit the Oponal: operaons me duraons.
Move the cursor to the me duraon and drag the on the bar to theme duraon meline
desired when the cursor turns to .posion
Click the me duraon and directly edit the start/end in the appeared dialog.me
Move the cursor to the start or the end of and drag to lengthen or shortenme duraon
the when the cursor turns to .me duraon
4) Oponal: Select the that need to be deleted, and then click in theme duraon(s)
Operaon column to delete the selected me duraon(s).
5) Click in the column to clear all the in the bar.Oponal: Operaon me duraon(s) me
6) Click in the column to delete this added holiday period from theOponal: Operaon
holiday list.
6. Click Save.
9.5.2 Add Template
Template includes week schedule and holiday. You can set week schedule and assign the me
duraon authorizaon dierent of access for person or group. You can also select the added
holiday(s) for the template.
Steps
Note
You can add up to 255 templates in the soware system.
DS-K281X Series Access Controller User Manual
47
1. Click Access Control → Schedule → Template to enter the Template page.
Note
There are two default templates: All-Day Authorized and All-Day Denied, and they cannot be
edited or deleted.
All-Day Authorized
The access is valid in each day of the week and it has no holiday.authorizaon
All-Day Denied
The access is invalid in each day of the week and it has no holiday.authorizaon
2. Click on the panel to create a new template.Add le
3. Create a name for the template.
4. Enter the or some descripons nocaon of this template in the Remark box.
5. Edit the week schedule to apply it to the template.
1) Click Week Schedule tab on the lower panel.
2) Select a day of the week and draw me duraon(s) meline on the bar.
Note
Up to 8 me duraon(s) can be set for each day in the week schedule.
3) Perform the following Oponal: operaons to edit the me duraons.
Move the cursor to the me duraon and drag the me duraon meline on the bar to the
desired posion when the cursor turns to .
Click the and directly edit the start/end in the appeared dialog.me duraon me
Move the cursor to the start or the end of and drag to lengthen or shortenme duraon
the me duraon when the cursor turns to .
4) Repeat the two steps above to draw more on the other days of the week.me duraons
6. Add a holiday to apply it to the template.
Note
Up to 4 holidays can be added to one template.
1) Click tab.Holiday
2) Select a holiday in the le list and it will be added to the selected list on the right panel.
3) Click to add a new holiday.Oponal: Add
Note
For details about adding a holiday, refer to .Add Holiday
4) Select a selected holiday in the right list and click to remove the selected one, orOponal:
click to clear all the selected holiday(s) in the right list.Clear
7. Click Save to save the
sengs nish and adding the template.
DS-K281X Series Access Controller User Manual
48
9.6 Set Access Group to Assign Access Authorizaon to Persons
Aer conguring credenals, adding the person and the person's you can create the access groups
to which person(s) can get access to which door(s) and then apply the access group to thedene
access control device to take eect.
Steps
For one person, you can add up to 4 access groups to one access control point of one device.
You can add up to 128 access groups in total.
When the access group sengs are changed, you need to apply the access groups to the devices
again to take eect. The access group changes include changes of template, access group
sengs, person's access group and related person details (including card number,sengs,
ngerprint, face picture, linkage between card number and linkage between cardngerprint,
number and card password, card ngerprint, eecve period, etc).
1. Click Access Control → Access Group to enter the Access Group interface.
2. Click to open the Add window.Add
3. In the text Name eld, create a name for the access group as you want.
4. Select a template for the access group.
Note
You should the template before access group Refer to congure sengs. Congure Schedule
and Template for details.
5. In the list of the Select Person select person(s) and the person(s) will be added to thele eld,
selected list .
6. In the le eld, staon(s) list of the Select Door select door(s) or door for the selected persons
to access, and the selected door(s) or door will be added to the selected list.staon(s)
7. Click .OK
8. Aer adding the access groups, you need to apply them to the access control device to take
eect.
1) Select the access group(s) to apply to the access control device.
To select mulple access groups, you can hold the or key and select access groups.Ctrl Shi
2) Click to start applying all the selected access group(s) to the accessApply All to Devices
control device or door staon.
Cauon
Be careful to click Apply All to Devices, since this operaon will clear all the access groups
of the selected devices and then apply the new access group, which may brings risk to the
devices.
You can click Apply Changes to Devices to only apply the changed part of the selected
access group(s) to the device(s).
3) View the apply status in the Status column or click Applying Statusto view all the applied
access group(s).
DS-K281X Series Access Controller User Manual
49
The selected persons in the applied access groups will have the authorizaon to enter/exit the
selected doors/door staons with their linked card(s) or ngerprints.
9. Oponal: Click to edit the access group if necessary.
9.7 Advanced Congure Funcons
You can the advanced of access control to meet some special requirements incongure funcons
dierent scene.
Note
For the card related type of access control card), only the card(s) with access groupfuncons(the
applied will be listed when adding cards.
The advanced should be supported by the device.funcons
Hover the cursor on the Advanced Funcon, and then Click to customize the advanced
funcon(s) to be displayed.
9.7.1 Remaining Unlocked/LockedCongure
You can set the status of the door as unlocked or locked and set the elevator controller as free and
controlled. For example, you can set the door remaining locked in the holiday, and set the door
remaining unlocked in the specied period of the work day.
Before You Start
Add the access control devices to the system.
Steps
1. Click Access Control → Advanced → Remain Locked/UnlockedFuncon to enter the Remain
Locked/Unlocked page.
2. Select the door or elevator controller that need to be congured le on the panel.
3. To set the door or elevator controller status during the work day, click the andWeek Schedule
perform the following operaons.
1) For door, click Remain Unlocked Remain Locked or .
2) For elevator controller, click or Free Controlled.
3) Drag the cursor to draw the me duraon, which means in that of theduraon me,
congured acvated. access group is
Note
Up to 8 me duraons can be set to each day in the week schedule.
4) Perform the following Oponal: operaons me duraons. to edit the
DS-K281X Series Access Controller User Manual
50
Move the cursor to the me duraon me duraon meline and drag the on the bar to the
desired when the cursor turns to .posion
Click the and directly edit the start/end in the appeared dialog.me duraon me
Move the cursor to the start or the end of me duraon and drag to lengthen or shorten
the me duraon when the cursor turns to .
5) Click Save.
Related Operaons
Copy to Whole
Week
Select one on the bar, click duraon me Copy to Whole Week to copy all
the on this bar to other week days.duraon sengs me
Delete Selected Select one on the bar, click duraon me Delete Selected to delete this
duraon.
Clear ClearClick to clear all the duraon sengs in the week schedule.
4. To set the door status during the holiday, click the Holiday and perform the following operaons.
1) Click Remain Unlocked Remain Locked or .
2) Click .Add
3) Enter the start date and end date.
4) Drag the cursor to draw the me duraon, which means in that of theduraon me,
congured acvated. access group is
Note
Up to 8 me duraons can be set to one holiday period.
5) Perform the following operaons me duraons. to edit the
Move the cursor to the me duraon me duraon meline and drag the on the bar to the
desired when the cursor turns to .posion
Click the me duraon and directly edit the start/end in the appeared dialog.me
Move the cursor to the start or the end of and drag to lengthen or shortenme duraon
the me duraon when the cursor turns to .
6) Select the that need to be deleted, and then click in theOponal: me duraon(s)
Operaon column to delete the selected me duraon(s).
7) Click in the column to clear all the in the bar.Oponal: Operaon me duraon(s) me
8) Click in the Oponal: Operaon column to delete this added holiday period from the
holiday list.
9) Click Save.
5. Oponal: Copy toClick to copy the door status of this door to other door(s).sengs
9.7.2 Congure An-Passback
You can set to only pass the access control point according to the path and only onespecied
person could pass the access control point aer swiping the card.
Before You Start
Enable the back of the access control device.an-passing funcon
DS-K281X Series Access Controller User Manual
51
Perform this task when you want to congure an-passing the back for the access control device.
Steps
Note
Either the back or interlocking can be an-passing mul-door funcon congured for an access
control device at the same For the me. conguraon mul-door of interlocking, refer to
Congure Mul-door Interlocking .
1. Click Access Control → Advanced Funcon An-Passback to enter the An-Passpack Sengs
page.
2. Select an access control device on the le panel.
3. Select a card reader as the beginning of the path in the First Card Reader eld.
4. Click of the selected rst card reader in the Card Reader Aerward column to open the select
card reader dialog.
5. Select the aerward card readers for the rst card reader.
Note
Up to four card readers can be added as aerward aerward card readers for one card reader.
6. Click in the dialog to save the OK selecons.
7. Click Save in the page to save the and take An-Passback Sengs sengs eect.
Example
Set Card Swiping Path
If you select Reader In_01 as the beginning, and select Reader In_02, Reader Out_04 as the linked
card readers. Then you can only get through the access control point by swiping the card in the
order as Reader In_01, Reader In_02 and Reader Out_04.
9.7.3 Congure Mul-door Interlocking
You can set the interlocking between doors of the same access control device.mul-door mulple
To open one of the doors, other doors must keep closed. That means in the interlocking combined
door group, up to one door can be opened at the same me.
Before You Start
Add access control device to the client, and make sure the device supports the mul-door
interlocking funcon.
DS-K281X Series Access Controller User Manual
52
Steps
Note
Mul-door funcon Interlocking is only supported by the access control device which has more
than one access control points (doors).
Either the back or interlocking can be an-passing mul-door funcon congured for an access
control device at the same me. conguraon an-passing funcon, For the of back refer to
Congure An-Passback .
1. Click Access Control → Advanced Interlocking Funcon Mul-door .
2. Select an access control device on the panel.le
3. Click on the Interlocking List panel to open Add Access Control Point to open theAdd Mul-door
Add window.
4. Select at least two access control points(doors) from the list.
Note
Up to four doors can be added in one interlocking mul-door combinaon.
5. Click to add the selected access control point(s) for interlocking.OK
The congured mul-door combinaon Mul-door interlocking will list on the Interlocking List
panel.
6. Oponal: Select an added interlocking from the list and click mul-door combinaon Delete to
delete the combinaon.
7. Click to apply the to the access control device.Apply sengs
9.7.4 Congure First Person In
You can set persons for one access control point. the mulple rst Aer rst person is authorized,
it allows persons access the door or other mulple authencaon acons.
Before You Start
Add access control device to the client, and make sure the device supports the rst person in
funcon.
Add person and assign access authorizaon to designed person. For details, refer to Person
Management Set Access Group to Assign Access and Authorizaon to Persons .
Steps
1. Click Access Control → Advanced Funcon → First Person In to enter the First Person In page.
2. Select an access control device in the list on the panel.le
3. Select the current mode as Enable Remaining Open First Person Disable Remaining Openaer ,
aer First Person by First Person , or Authorizaon from the drop-down list for each access
control point of the selected device.
Enable Remaining Open aer First Person
DS-K281X Series Access Controller User Manual
53
The door remains open for the congured me duraon aer rst the person is authorized
unl duraon the remain open ends. If you select this mode, you should set the consecuve
authencaon mes and interval of consecuve authencaon.
Note
The remain open duraon should be between 0 and 1440 minutes. By default, the remain
open is 10 minutes.duraon
Disable Remaining Open First Personaer
Disable the of funcon rst authencaon. person in, namely normal
Authorizaon by First Person
All (except for the of super card, super password, duressauthencaons authencaons
card, and duress code) are allowed only aer rst authorizaon. the person
Note
You can authencate rst by the person again to disable the rst person mode.
4. Click on the First Person List panel.Add
5. Select person(s) in the le list and the person(s) will be add to the selected persons as the rst
person(s) of the doors.
The added rst person(s) will list in the First Person List
6. Oponal: Select a rst person from the list and click to remove the person from the Delete rst
person list.
7. Click Save.
9.7.5 Congure Mul-Factor Authencaon
You can manage the persons by group and set the for persons of oneauthencaon mulple
access control point (door).
Before You Start
Set access group and apply the access group to the access control device. For details, refer to Set
Access Group to Assign Access Authorizaon to Persons .
Perform this task when you want to set authencaons for cards of one access controlmulple
point (door).
Steps
1. Click Access Control → Advanced Funcon Mul-Factor Auth .
2. Select an access control device in device list on the le panel.
3. Add a person/card group for the access control device.
1) Click on the right panel.Add
2) Create a name for the group as desired.
3) Specify the start me me eecve and end of the period for the person/card group.
DS-K281X Series Access Controller User Manual
54
4) Select members(s) and card(s) in the Available list, and the selected member(s) and card(s)
will be added to the Selected list.
Note
Make sure you have issue card to the person.
Make sure you have set access group and apply the access group to the access control device
successfully.
5) Click Save.
6) Oponal: Select the person/card group(s), and then click Delete to delete it(them).
7) Select the person/card group(s), and then click to re-apply access group thatOponal: Apply
failed to be applied previously to the access control device.
4. Select an access control point (door) of selected device on the le panel.
5. Enter the maximum interval when entering password.
6. Add an authencaon group for the selected access control point.
1) Click on the Groups panel.Add Authencaon
2) Select a congured template as the template from the drop-down list.authencaon
Note
For the template, refer to seng Congure Schedule and Template .
3) Select the type as , authencaon Local Authencaon Local and RemotelyAuthencaon
Open Door Local and Super Password, or Authencaon from the drop-down list.
Local
Authencaon
Authencaon by the access control device.
Local and Remotely Open DoorAuthencaon
Authencaon by the access control device and by the client. When the person swipes the
card on the device, a window will pop up. You can unlock the door via the client.
Figure 9-2 Remotely Open Door
DS-K281X Series Access Controller User Manual
55
Note
You can check to enable the super password whenOine Authencaon authencaon
the access control device is disconnected with the client.
Local and Super PasswordAuthencaon
Authencaon by the access control device and by the super password.
4) Select the added person/card group in the le list below and it will be added to the Selected
list on the right as the group.authencaon
5) Click the added group in the right list to set in the Authauthencaon authencaon mes
Times column.
Note
The should be larger than 0 and smaller than the added personnelauthencaon mes
quanty in the personnel group.
6) Click Save.
Note
For each access control point (door), up to four groups can be added.authencaon
For the group of which type is , up to 8authencaon authencaon Local Authencaon
person/card groups can be added to the group.authencaon
For the authencaon authencaon group of which type is Local and SuperAuthencaon
Password Local or Authencaon and Remotely Open Door, up to 7 person/card groups can
be added to the authencaon group.
7. Click Save.
9.7.6 Congure Card Reader Authencaon Mode and Schedule
You can set the passing rules for the card reader of the access control device according to your
actual needs.
Steps
1. Click Access Control → Advanced Funcon Authencaon to enter the modeauthencaon
conguraon page.
2. Select a card reader on the to le congure.
3. Set card reader mode.authencaon
1) Click Conguraon.
DS-K281X Series Access Controller User Manual
56
Figure 9-3 Select Card Reader ModeAuthencaon
2) Check the modes in the Available Mode list and they will be added to the selected modes list.
3) Click .OK
Aer selecng the modes, the selected modes will display as icons with dierent color.
4. Click the icon to select a card reader mode, and drag the cursor to draw a colorauthencaon
bar on the schedule, which means in that period of the card reader is valid.me, authencaon
5. Repeat the above step to set other me periods.
6. Oponal: Select a day and click congured Copy to Week to copy the same to the wholesengs
week.
7. Oponal: Copy toClick to copy the to other card readers.sengs
8. Click Save.
DS-K281X Series Access Controller User Manual
57
9.7.7 Device ParametersCongure
Aer adding the access control device, you can congure the parameters of access control device,
access control points.
Congure Parameters for Access Control Device
Aer adding the access control device, you can congure its parameters, including overlaying user
informaon aer on picture, uploading pictures capturing, saving captured pictures, etc.
Before You Start
Add access control device to the client.
Steps
1. Click Access Control Advanced Funcon → Device Parameters .
Note
If you can not Device Parameter in the Advanced list, hover the cursor on thend Funcon
Advanced and then Click to select the Device Parameter to be displayed.Funcon,
2. Select an access device to show its parameters on the right page.
3. Turn the switch to ON to enable the corresponding funcons.
Note
The displayed parameters may vary for dierent access control devices.
Some of the following parameters are not listed in the Basic Informaon page, click toMore
edit the parameters.
Enable NFC
If enable the the device can recognize the NFC card. You can present NFC card onfuncon,
the device.
Enable M1 Card
If enable the the device can recognize the M1 card. You can present M1 card on thefuncon,
device.
Enable EM Card
If enable the funcon, the device can recognize the EM card. You can present EM card on the
device.
Enable CPU Card
Reserved. If enable the the device can recognize the CPU card. You can present CPUfuncon,
card on the device.
Enable ID Card
DS-K281X Series Access Controller User Manual
58
Reserved. If enable the the device can recognize the ID card. You can present IDfuncon,
card on the device.
4. Click .OK
5. Oponal: Copy toClick , and then select the access control device(s) to copy the parameters in
the page to the selected device(s).
Congure Parameters for Door
Aer adding the access control device, you can congure its access point (door) parameters.
Steps
1. Click Access Control → Advanced Funcon → Device Parameter .
2. Select an access control device on the panel, and then click to show the doors or ofle oors
the selected device.
3. Select a door or oor to show its parameters on the right page.
4. Edit the door or parameters.oor
Note
The displayed parameters may vary for dierent access control devices.
Some of the following parameters are not listed in the Basic Informaon page, click toMore
edit the parameters.
Name
Edit the card reader name as desired.
Door Contact
You can set the door sensor as remaining closed or remaining open. Usually, it is remaining
closed.
Exit Buon Type
You can set the exit as remaining closed or remaining open. Usually, it is remainingbuon
open.
Open Duraon
The door contact can be enabled with appropriate delay person with extended accesssaer
needs swipes her/his card.
Door Le Open Timeout Alarm
The alarm can be triggered if the door has not been closed in a period. If it iscongured me
set as 0, no alarm will be triggered.
Super Password
The person can open the door by the super password.specic inpung
5. Click to Advanced congure advanced parameters.
Extended Open Duraon
DS-K281X Series Access Controller User Manual
59
The door contact can be enabled with appropriate delay person with extended accesssaer
needs swipes her/his card.
Duress Code
The door can open by the duress code when there is duress. At the same theinpung me,
client can report the duress event.
Enable Locking Door when Door Closed
The door can be locked once it is closed even if the is not reached.Door Locked Time
Dismiss Code
Create a dismiss code which can be used to stop the buzzer of the card reader (by entering
the dismiss code on the keypad).
Note
The duress code and super password should be dierent.
The duress code and super password should be dierent authencaon from the password.
The length of duress code and super password is according the device, usually it should
contains 4 to 8 digits.
6. Click .OK
7. Oponal: Copy toClick , and then select the door to copy the parameters in the page to the
selected doors.
Note
The door or status will be copied to the selected door as well.oor's duraon sengs
Congure Parameters for Card Reader
Aer adding the access control device, you can its card reader parameters.congure
Steps
1. Click Access Control → Advanced → Device Parameter Funcon .
2. In the device list on the click to expand the door, select a card reader and you can edit thele,
card reader's parameters on the right.
3. Edit the card reader basic parameters in the Basic Informaon page.
Note
The displayed parameters may vary for dierent access control devices. There are part of
parameters listed as follows. Refer to the user manual of the device for more details.
Some of the following parameters are not listed in the Basic page, click Informaon More to
edit the parameters.
Name
Edit the card reader name as desired.
DS-K281X Series Access Controller User Manual
60
Card IntervalAuthencaon
If the interval between card swiping of the same card is less than the set value, the card
swiping is invalid. You can set it as 0 to 255.
Enable Failed Limit of Aempts Authencaon
Enable to report alarm when the card reading reach the set value.aempts
Card Reader Type/Card Reader Descripon
Get card reader type and They are read-only.descripon.
4. Click and you can Advanced congure more parameters.
Enable Card Reader
Enable the and you can operate the below on the card reader.funcon funcons
OK LED Polarity/Error LED Polarity/Buzzer Polarity
Set OK LED Polarity/Error LED Polarity/Buzzer LED Polarity of main board according to the
card reader parameters. Generally, adopts the default sengs.
Buzzer Polarity
Set Buzzer Polarity of main board according to the card reader parameters. Generally, adopts
the default sengs.
Buzzing Time
Set the card reader buzzing The available ranges from 0 to 5,999s. 0 representsme. me
connuous buzzing.
Max. Interval When Entering PWD
When you the password on the card reader, if the interval between pressing twoinpung
digits is larger than the set value, the digits you pressed before will be cleared automacally.
Tampering Detecon
Enable the an-tamper detecon for the card reader.
Communicate with Controller Every
When the access control device cannot connect with the card reader for longer than the set
me, the card reader will turn oine automacally.
Fingerprint Recognion Level
Select the ngerprint recognion level from the drop-down list.
5. Click .OK
6. Oponal: Copy toClick , and then select the card reader(s) to copy the parameters in the page to
the selected card reader(s).
Congure Parameters for Alarm Output
Aer adding the access control device, if the device links to alarm outputs, you can congure the
parameters.
DS-K281X Series Access Controller User Manual
61
Before You Start
Add access control device to the client, and make sure the device supports alarm output.
Steps
1. Click Access Control → Advanced Funcon → Device Parameter to enter access control
parameter conguraon page.
2. In the device list on the click to expand the door, select an alarm input and you can editle,
the alarm input's parameters on the right.
3. Set the alarm output parameters.
Name
Edit the card reader name as desired.
Alarm Output Acve Time
How long the alarm output will last triggered.aer
4. Click .OK
5. Oponal: Set the switch on the upper right corner to to trigger the alarm output.ON
9.7.8 Congure Device Parameters
Aer adding the access control device, you can set its parameters such as network parameters.
Enable M1 Card Encrypon
M1 card can improve the security level of encrypon authencaon.
Steps
Note
The should be supported by the access control device and the card reader.funcon
1. Enter the Access Control module.
2. On the navigaon le, bar on the enter Advanced Funcon → More Parameters .
3. Select an access control device in the device list and click M1 Card
Encrypon to enter the M1
Card page.Encrypon
4. Set the switch to on to enable the M1 card encrypon funcon.
5. Set the sector ID.
The sector ID ranges from 1 to 100.
6. Click Save to save the
sengs.
DS-K281X Series Access Controller User Manual
62
9.8 Door Control
In Monitoring module, you can view the status of the doors managed by the addedreal-me
access control device. You can also control the doors such as open/close the door, or remain the
door open/closed via the client remotely. The access event are displayed in this module.real-me
You can view the access details and person details.
Note
For the user with door control permission, the user can enter the Monitoring module and control
the door. Or the icons used for control will not show. For the user permission, refer toseng
Person Management .
9.8.1 Control Door Status
You can control the status for a single door, including opening door, closing door, remaining the
door open, and remaining the door closed.
Steps
1. Click to enter the status monitoring page.Monitoring
2. Select an access point group on the upper-right corner.
Note
For managing the access point group, refer to in the user manual of theGroup Management
client soware.
The doors in the selected access control group will display.
3. Click a door icon to select a door, or press and select Ctrl mulple doors.
4. Click the following to control the door.buons
Open Door
When the door is locked, unlock it and it will be open for once. Aer duraon, the open the
door will be closed and locked again automacally.
Close Door
When the door is unlocked, lock it and it will be closed. The person who has the access
authorizaon can access the door with credenals.
Remain Open
The door will be unlocked (no closed or open). All the persons can access the doormaer
with no required.credenals
Remain Closed
The door will be closed and locked. No person can access the door even if he/she has the
authorized except the super users.credenals,
DS-K281X Series Access Controller User Manual
63
Capture
Capture a picture manually.
Note
The is available when the device supports capture The picture isCapture buon funcon.
saved in the PC running the client. For the saving path, refer to seng Set File Saving Path in
the user manual of the client soware.
Result
The icon of the doors will change in according to the real-me operaon operaon if the is
succeeded.
9.8.2 Check Real-Time Access Records
The access records will display in real including card swiping records, comparisonme, ngerprint
records, etc. You can view the person informaon and view the picture captured during access.
Steps
1. Click and select a group from the drop-down list on the upper-right corner.Monitoring
The access records triggered at the doors in the selected group will display in real me. You can
view the details of the records, including card No., person name, organizaon, event etc.me,
2. Oponal: Check the event type and event status so that these events will show in the list if the
events are detected. The events of unchecked type or status will not be displayed in the list.
3. Oponal: Show Latest EventCheck and the latest access record will be selected and displayed at
the top of the record list.
4. Oponal: Click the event to view the accessed person details, including person pictures
(captured picture and prole), person No., person name, organizaon, phone, contact address,
etc.
Note
You can double click the captured picture to enlarge it to view the details.
5. Oponal: Right click on the column name of the access event table to show or hide the column
according to actual needs.
DS-K281X Series Access Controller User Manual
64
Appendix A. Tips for Scanning Fingerprint
Recommended Finger
Forenger, nger nger. middle or the third
Correct Scanning
The displayed below is the correct way to scan your gure nger:
You should press your on the scanner horizontally. The center of your scanned shouldnger nger
align with the scanner center.
Incorrect Scanning
The of scanning gures ngerprint displayed below are incorrect:
DS-K281X Series Access Controller User Manual
65
Environment
The scanner should avoid direct sun light, high temperature, humid condions and rain.
When it is dry, the scanner may not recognize your ngerprint successfully. You can blow your
nger and scan again.
Others
If your ngerprint is shallow, or it is hard to scan your we recommend you to use otherngerprint,
authencaon methods.
If you have injuries on the scanned nger, the scanner may not recognize. You can change another
nger and try again.
DS-K281X Series Access Controller User Manual
66
Appendix B. DIP Switch Descripon
No.1 to No 8 is from the low bit to the high bit.
When the switch is towards ON, it means the switch is enabled, otherwise, the switch is o. If you
set the DIP switch like the gure displayed below, its binary value is 00001100, and its decimal
value is 12.
DS-K281X Series Access Controller User Manual
67
Appendix C. Custom Wiegand Rule Descripons
Take Wiegand 44 as an example, the values in the Custom Wiegand tab are as follows:seng
Custom Wiegand
Name
Wiegand 44
Total Length 44
Transformaon Rule
(Decimal Digit)
byFormatRule[4]=[1][4][0][0]
Parity Mode XOR Parity
Odd Parity Start Bit Length
Even Parity Start Bit Length
XOR Parity Start Bit 0 Length per Group 4 Total Length 40
Card ID Start Bit 0 Length 32 Decimal Digit 10
Site Code Start Bit Length Decimal Digit
OEM Start Bit Length Decimal Digit
Manufacturer Code
Start Bit
32 Length 8 Decimal Digit 3
Wiegand Data
Wiegand Data = Valid Data + Parity Data
Total Length
Wiegand data length.
Transportaon Rule
4 bytes. Display the types of valid data. The example displays the of Cardcombinaon combinaon
ID and Manufacturer Code. The valid data can be single rule, or combinaon mulple of rules.
Parity Mode
Valid parity for Wiegand data. You can select either odd parity or even parity.
Odd Parity Start Bit, and Length
If you select Odd Parity, these items are available. If the odd parity start bit is 1, and the length is
12, then the system will start odd parity from bit 1. It will calculate 12 bits. The resultcalculaon
will be in bit 0. (Bit 0 is the rst bit.)
DS-K281X Series Access Controller User Manual
68
Even Parity Start Bit, and Length
If you select Even Parity, these items are available. If the even parity start bit is 12, and the length is
12, then the system will start even parity from bit 12. It will calculate 12 bits. The resultcalculaon
will be in the last bit.
XOR Parity Start Bit, Length per Group, and Total Length
If you select XOR Parity, these items are available. Depending on the table displayed above, the
start bit is 0, the length per group is 4, and the total length is 40. It means that the system will
calculate from bit 0, calculate every 4 bit, and calculate 40 bits in total (10 groups in total). The
result will be in the last 4 bits. (The result length is the same as the length per group.)
Card ID Start Bit, Length, and Decimal Digit
If you use the transformaon rule, these items are available. Depending on the table displayed
above, the card ID start bit is 0, the length is 32, and the decimal digit is 10. It represents that from
bit 0, there are 32 bits represent the card ID. (The length here is calculated by bit.) And the decimal
digit length is 10 bits.
Site Code Start Bit, Length, and Decimal Digit
If you use the transformaon rule, these items are available. For detailed see theinformaon,
explanaon of the card ID.
OEM Start Bit, Length, and Decimal Digit
If you use the transformaon rule, these items are available. For detailed see theinformaon,
explanaon of the card ID.
Manufacturer Code Start Bit, Length, and Decimal Digit
If you use the transformaon rule, these items are available. Depending on the table displayed
above, the manufacturer code start bit is 32, length is 8, and decimal digit is 3. It represents that
from bit 32, there are 8 bits are manufacturer code. (The length here is calculated by bit.) And the
decimal length is 3.
DS-K281X Series Access Controller User Manual
69
Appendix D. Matrix and DeviceCommunicaon
Command
Communicaon Matrix
Scan the following QR code to get the device matrix.communicaon
Note that the matrix contains all communicaon ports of Hikvision access control and video
intercom devices.
Figure D-1 QR Code of MatrixCommunicaon
Device Command
Scan the following QR code to get the device common serial port commands.
Note that the command list contains all commonly used serial ports commands for all Hikvision
access control and video intercom devices.
Figure D-2 Device Command
DS-K281X Series Access Controller User Manual
70
UD31244B-A

Problemløsning Hikvision DS-K2814

Hvis du har læst manualen omhyggeligt, men ikke fundet en løsning på dit problem, bed andre brugere om hjælp


Specifikationer

Mærke: Hikvision
Kategori: sikkerhedsadgangskontrolsystem
Model: DS-K2814