© 2021 all rights reserved to Festo SE & Co. KG
1 Applicable documents
All available documents for the product
è www.festo.com/sp.
2 Safety
2.1 Safety instructions
Only use the product in its original condition without unauthorised modifica-
tions.
Only use the product if it is in perfect technical condition.
Take the weight of an individual device or a service unit into account.
Dependent on the design, a mounted service unit can weigh more than 100 kg.
Under intended use the surface temperature may reach 60 °C. Allow the device
to cool down before working on it.
Make sure the mounting surface is sufficiently strong for the maximum forces.
Only use suitable mounting components.
Mount the individual device or the service unit only on flat surfaces.
2.2 Intended use
The sub-base PAML-CP serves as an adapter for the pneumatic connection and
for pipe mounting for in-line installation of service units.
The module connector PAML-MK is used to connect two service units of the
same size.
2.3 Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can eval-
uate the work and detect dangers. Personnel must have the relevant mechanical
training.
3 Additional Information
Accessories è www.festo.com/catalogue.
4 Product Range Overview
4.1 Scope of delivery
1
2
3
4
5
Fig. 1: Sub-base PAML-CP
1
Front plate (1x)
2
Rear plate (1x)
3
Screw (8x)
4
Washer (8x)
5
O-ring (2x)
6
7
8
9
Fig. 2: Module connector PAML-MK
6
Screw (2x)
7
Front plate (1x)
8
O-ring (1x)
9
Rear plate (1x)
4.2 Not in scope of delivery
10 11
Fig.3
10
Electrical pressure regulator (1x)
PREL-186
11
Micro filter (1x)
PFML-186
5 Assembly
5.1 Mounting the connecting plates PAML-CP
1
2
3
4
5
12
Fig.4
1. Orient the front plate and the rear plate so the stamp number on the1 2
sub-base corresponds with the stamp number on the housing (1 to 1 and 2 to
2) and the mounting thread for wall mounting points to the rear.aB
2. Insert the O-rings in the slots provided.5
3. Position the front plate and the rear plate .1 2
4. Fasten the front plate and the rear plate to the service unit using four1 2
screws and four washers . Tightening torque: 27 Nm ± 15% 3 4
5. Comply with the maximum screw-in depth for the pipe connection.
ISO 228 Max. screw-in depth [mm]
G1/2 12
G1 1/4 20
G1 1/2 22
G2 24
G2 1/2 26

Problemløsning Festo PAML-CP-186-HP3-G14

Hvis du har læst manualen omhyggeligt, men ikke fundet en løsning på dit problem, bed andre brugere om hjælp


Specifikationer

Mærke: Festo
Kategori: Ikke kategoriseret
Model: PAML-CP-186-HP3-G14

Lignende produkter

Ikke kategoriseret - 2 Sider
Ikke kategoriseret - 6 Sider
Ikke kategoriseret - 1 Sider
Ikke kategoriseret - 4 Sider
Ikke kategoriseret - 3 Sider
Ikke kategoriseret - 2 Sider
Ikke kategoriseret - 4 Sider
Ikke kategoriseret - 2 Sider
Ikke kategoriseret - 2 Sider
Ikke kategoriseret - 7 Sider